Functional safety technical resource

What Is Failure Rate (Lambda)?

Failure rate, commonly represented by the Greek letter lambda, is a reliability-modeling measure of how frequently a defined type of failure occurs over a stated exposure time for a specified item or population. In safety instrumented system (SIS) work, a rate is meaningful only when its failure definition, units, equipment boundary, data source, operating conditions, and statistical assumptions are known.

Technical resource from Mangan Safety Instrumented Systems (Mangan SIS)

How Failure Rates Are Classified for SIS Work

A total random hardware failure rate is commonly partitioned according to the effect on the safety function and whether the failure is detected. Categories can include safe detected, safe undetected, dangerous detected, and dangerous undetected failures. These labels are application-dependent: the same physical fault may have a different safety effect for a different function or safe state. The classification should therefore be tied to a defined SIF, component boundary, diagnostic behavior, and failure-mode analysis instead of copied from a generic equipment description.

Where Failure-Rate Data Comes From

Potential sources include device assessment reports, supplier safety documentation, industry reliability databases, and documented operating experience. Each source has a population, observation period, inclusion rules, confidence limits, environmental profile, maintenance practice, and treatment of censored or incomplete data. Before using a value, the analyst should confirm that the device variant and application are comparable and that the rate represents the intended failure category. A precise-looking number is not necessarily a strong input when its provenance or uncertainty is missing.

Model Assumptions Behind Lambda

Many SIS calculations use a constant failure-rate assumption over an equipment's useful-life region. That assumption simplifies probability models but may not represent early-life defects, wear-out, severe service, dormant mechanisms, or changing maintenance quality. Repair, proof testing, diagnostic intervals, common-cause failures, and dependent utilities must be modeled separately where relevant. Units must remain consistent throughout the calculation, and conversions should be visible so a rate per hour is not inadvertently combined with an interval expressed in another unit.

Best Practices for Using Failure Rates

Record the data source, revision, item boundary, failure definition, units, operating environment, and any confidence or applicability limitations. Use the same failure taxonomy throughout the device data, SIF model, and test strategy. Compare assumed rates with site demand and failure records, while recognizing that small site populations may not support a statistically stable estimate. Mangan SIS recommends sensitivity analysis for influential inputs and formal change control when a vendor revision, device substitution, service condition, or field history changes the basis of the calculation.

Mangan SIS project context

Apply Failure Rate (Lambda) to documented SIS decisions

Failure rates are inputs to quantitative models for SIF sensors, logic solvers, final elements, and supporting elements. They help estimate PFDavg, PFH, and spurious-trip behavior when combined with architecture, diagnostics, testing, repair, and common-cause assumptions. A failure rate should never be presented as a complete measure of SIF suitability.

Sources and scope

Use the source type that fits the decision

Standards

IEC 61508 provides the generic functional-safety framework, definitions, and hardware requirements used to classify random hardware failures. IEC 61511 applies these concepts to process-industry SIFs and SIS.

Guidance

IEC 61508-6:2010 provides guidance and examples for applying hardware-failure probability methods. The examples require application-specific inputs and should not be treated as universal data values.

Regulation

OSHA 29 CFR 1910.119 does not prescribe SIS failure-rate values. For covered processes, mechanical-integrity records, operating experience, process safety information, and management of change can affect how reliability assumptions are maintained.

Mangan recommendation

Mangan SIS recommends using traceable, category-specific failure data matched to the device, service, and SIF boundary, with units, uncertainty, modeling assumptions, and changes documented.

Primary references

Common questions

Clarifying Failure Rate (Lambda)

Is failure rate the same as probability of failure?

No. A failure rate describes event frequency relative to exposure time under stated assumptions. A probability over an interval is derived using a model and additional assumptions.

Can one lambda value be used for every application of a device?

Not without evaluation. Failure effects, diagnostics, environment, maintenance, configuration, and service conditions can differ, so the rate and its classification must be checked for applicability.

Why split lambda into safe and dangerous categories?

SIS models need to distinguish failures by their effect on the safety function and by detection status. Dangerous undetected, dangerous detected, and safe failures contribute differently to performance and operational behavior.

Need a defensible verification basis?

Review the data, assumptions, and evidence behind your SIF calculation.

Contact Mangan SIS

Downloadable term reference

Download: Failure Rate (Lambda) - Functional Safety Glossary PDF

Save or share this term-specific reference, including the answer-first definition, engineering review considerations, and primary-source references.

Download the Failure Rate (Lambda) PDF